2012 ©
             ข้อมูลการเผยแพร่ผลงาน
การเผยแพร่ในรูปของบทความวารสารทางวิชาการ
ชื่อบทความ Reliability and Validity of Mini-Balance Evaluation System Test in Type 2 Diabetic Patients with Peripheral Neuropathy 
วัน/เดือน/ปี ที่ได้ตอบรับ 6 มิถุนายน 2565 
วารสาร
     ชื่อวารสาร International journal of environmental research and public health (IJERPH)  
     มาตรฐานของวารสาร OTHER (JCR - Q1) 
     หน่วยงานเจ้าของวารสาร Journal by MDPI 
     ISBN/ISSN ISSN: 1660-4601 
     ปีที่ 2022 
     ฉบับที่ June 
     เดือน Voulume 19, Issue 11
     ปี พ.ศ. ที่พิมพ์ 2565 
     หน้า 12 
     บทคัดย่อ Type 2 diabetic peripheral neuropathy is known to cause balance limitations in static, dynamic, and functional activity. The Mini-BESTest, a shortened version of BESTest, was evolved to identify balance disorders within a short duration. No prior studies have yet been conducted to assess the usefulness of Mini-BESTest in the diagnosis of type 2 diabetic peripheral neuropa- thy. The current study aimed to examine the reliability and discriminant validity by comparing the Mini-BESTest scores between type 2 diabetic patients with peripheral neuropathy, divided into two 2 groups based on reporting scores of <4 and ≥4 in the MNSI questionnaire, respectively. There- fore, a cross-sectional study design was conducted including 44 type 2 diabetic patients ( 4 males and 40 females; aged 56.61 ± 7.7 years old). Diabetic peripheral neuropathy was diagnosed by physical assessment using the Michigan Neuropathy Screening Instrument (MNSI). Inter-rater (two physiotherapists) and Intra-rater (7–10 days) reliability of the Mini-BESTest were explored with intraclass correlation coefficients (ICC2,1) and (ICC3,1). The Mini-BESTest presented an excel- lent inter-rater reliability (ICC2,1= 0.95, 95% CI = 0.91–0.97, SEM = 0.61) and an excellent intra-rater reliability (ICC3,1 = 0.93, 95% CI = 0.87–0.96, SEM = 0.66), with confirmation by a good agreement presented by the Bland–Altman plots. The internal consistency measured with the overall Cronbach’s alpha showed an acceptable agreement (0.73). The MDC was 2.16. In addition, the Mini-BESTest scores in the type 2 diabetic neuropathy patients reporting MNSI questionnaire scores <4 was found to be significantly higher when compared with those reporting scores ≥4. The Mini-BESTest can be used as a highly reliable and valid clinical application in the population with type 2 diabetic peripheral neuropathy. 
     คำสำคัญ balance; diabetic peripheral neuropathy; Mini-BESTest 
ผู้เขียน
617090013-2 Ms. SITT NYEIN PHYU [ผู้เขียนหลัก]
คณะเทคนิคการแพทย์ ปริญญาเอก ภาคปกติ นานาชาติ

การประเมินบทความ มีผู้ประเมินอิสระ 
สถานภาพการเผยแพร่ ตีพิมพ์แล้ว 
วารสารมีการเผยแพร่ในระดับ นานาชาติ 
citation มี 
เป็นส่วนหนึ่งของวิทยานิพนธ์ เป็น 
แนบไฟล์
Citation 0