2012 ©
             ข้อมูลการเผยแพร่ผลงาน
การเผยแพร่ในรูปของบทความวารสารทางวิชาการ
ชื่อบทความ Optimal Design of Guide Vane for Improving Mini Hydro Power Plant Efficiency by using Twin Axis Vertical Turbine 
วัน/เดือน/ปี ที่ได้ตอบรับ 18 มิถุนายน 2566 
วารสาร
     ชื่อวารสาร International Energy Journal 
     มาตรฐานของวารสาร SCOPUS 
     หน่วยงานเจ้าของวารสาร REGIONAL ENERGY RESOURCES INFORMATION CENTER (RERIC) Department of Energy, Environment and Climate Change School of Environment, Resources and Development ASIAN INSTITUTE OF TECHNOLOGY 
     ISBN/ISSN ISSN 1513-718X 
     ปีที่  
     ฉบับที่  
     เดือน
     ปี พ.ศ. ที่พิมพ์ 2566 
     หน้า 231-244 
     บทคัดย่อ This research aimed to increase the efficiency of a pico-hydropower plant with Banki type turbines by installing a guide vane system as the inlet water control. It was observed that the inlet angle of attack and the number of turbine blades had affected the efficiency of the pico-hydropower plant. Moreover, a computational fluid dynamics (CFD) simulation was conducted for validation by creating a guide vane with inlet angles of 5 to 30 degrees and a turbine with 15–40 blades. The turbulent model in the SOLIDWORKS Simulation was selected as the fluid dynamic model. The simulation results statistically showed that the inlet angle of attack had a greater influence on the torque than the number of blades, with P-values of 1.1893x10-7 and 0.3915, respectively. The efficiency investigation using a 25-blade turbine with inlet angles of attack of 5, 10, 15, 20, 24, and 30 degrees, showed that the turbine with the 24-degree inlet angle of attack had exhibited the highest system efficiency at 45.83%. This research focused on vertical axis Banki turbine, which has been designed for electrical generation in irrigational canal only. In the practical demonstration, a 3-kW electrical generator system was installed across the canal, and the system efficiency was also investigated. The results showed that the maximum system efficiency was at 48% with a 0.7 m system head and a flow rate of 0.4 m3/s. This represents results which were higher than predicted from the simulation at 45.83% and a greater performance than that of the generating system without a guide vane at 34.96%. 
     คำสำคัญ Guide vane Hydropower Low head Turbine Twin turbine 
ผู้เขียน
647040018-5 นาย คณิศร ธนัฐวุฒิกร [ผู้เขียนหลัก]
คณะวิศวกรรมศาสตร์ ปริญญาเอก ภาคปกติ

การประเมินบทความ มีผู้ประเมินอิสระ 
สถานภาพการเผยแพร่ ได้รับการตอบรับให้ตีพิมพ์ 
วารสารมีการเผยแพร่ในระดับ นานาชาติ 
citation ไม่มี 
เป็นส่วนหนึ่งของวิทยานิพนธ์ เป็น 
แนบไฟล์
Citation 0