2012 ©
             Publication
Journal Publication
Research Title Investment Cost Analysis with Structural Design of Concrete Duct Bank Power Cables 
Date of Distribution 20 November 2018 
Conference
     Title of the Conference International Conference on Renewable Energy and Environment (ICREE 2018) 
     Organiser Vienna University of Technology 
     Conference Place Gusshausstrasse 25, 1040  
     Province/State Vienna, Austria 
     Conference Date 19 November 2018 
     To 21 November 2018 
Proceeding Paper
     Volume 18 
     Issue
     Page 14-15 
     Editors/edition/publisher  
     Abstract Capital investment in underground duct bank cables is very expensive. Therefore, the design and planning for underground power cables is important. It is often done with analysis of the power demands minimizing costs over the lifetime of the cables. This work presents an evaluation of underground power cable ampacity and the total costs during the anticipated operational life of the equipment. It was evaluated with variation of concrete duct bank dimensions. Analysis of ampacity depends on temperature. The thermal model of the current study uses a finite element method. The total costs evaluated by the economic model in terms of net present value analysis consist of the initial investment costs and the value of losses over the life of the cable. These were based on installation costs, load factors, annual load growth, the price of energy, the price of demand charges and the forecast discount rate. The results show that cable spacing parameters are a significant factor that influences ampacity. Ampacity can be improved while reducing the losses in power cables. This is because appropriate cable spacing can reduce the effect of Joule heating from neighboring cables. However, this leads to increased construction costs. The total costs of power cables over their lifetime can be reduced by decreasing the horizontal distance between the center of a casing pipe and the side edge of the concrete layer. This is because the contribution of reduced construction costs is more than that of the effect of increased losses. Therefore, the dimensions of the concrete duct bank significantly14 influence ampacity, the construction costs and the losses of power cables in an analysis of total costs over the lifetime of power cables. 
Author
595040120-5 Mr. KAWIN CHARERNDEE [Main Author]
Engineering Master's Degree

Peer Review Status มีผู้ประเมินอิสระ 
Level of Conference นานาชาติ 
Type of Proceeding Abstract 
Type of Presentation Oral 
Part of thesis true 
Presentation awarding false 
Attach file
Citation 0