ชื่อบทความ |
Selective fluorescence sensors for p-phenylenediamine using formyl boronate ester with an assistance of micelles |
วัน/เดือน/ปี ที่ได้ตอบรับ |
17 กรกฎาคม 2555 |
วารสาร |
ชื่อวารสาร |
Sensors and Actuators B |
มาตรฐานของวารสาร |
|
หน่วยงานเจ้าของวารสาร |
Elsevier |
ISBN/ISSN |
|
ปีที่ |
|
ฉบับที่ |
173 |
เดือน |
|
ปี พ.ศ. ที่พิมพ์ |
2555 |
หน้า |
|
บทคัดย่อ |
A selective fluorometric approach for detection of p-phenylenediamine (PPD) was fabricated using the
alizarin–boronic acid adduct with an assistance of micelles. When Alizarin Red S (ARS) reacted with 4-
formylphenylboronic acid (4-FPBA) and yielded the boronate ester adduct (ARS/4-FPBA), the fluorescence
emission turned on. However, upon the addition of PPD, the fluorescence intensity of the ARS/4-FPBA
adduct decreased as a linear function of PPD concentrations. Enhancements in sensitivity and selectivity
of this fluorescence sensor were studied by incorporating the sensor molecule into the hydrophobic core
of micelles. The results showed significant improvement in sensitivity and selectivity comparing to the
sensor in the buffer solution. Parameters affecting the fluorescence quenching of boronate ester adducts
by PPD such as solution pH, 4-FPBA concentration, types of surfactants and surfactant concentrations
were investigated. The optimum conditions for the determination of PPD was 2.0 mM cetyltrimethylammonium
bromide (CTAB) in 50 mM phosphate buffer solution pH 7.0. The fluorescence intensity of the
ARS/4-FPBA adduct in the presence of CTAB was remarkably 11 times as high as that in the buffer solution.
The linear working concentration range was found to be 0.03–0.40 mM and the calibration sensitivity was
48 times higher than that from the system containing only buffer solution. Moreover, PPD exhibited the
highest calibration sensitivity among the studied primary amines, confirming that the proposed sensor
provided high sensitivity and good selectivity for PPD. The proposed sensor was used to determine PPD
in spiked water samples satisfactorily. |
คำสำคัญ |
p-Phenylenediamine, Micelle, Fluorescence sensors, Chemical sensors |
ผู้เขียน |
|
การประเมินบทความ |
มีผู้ประเมินอิสระ |
สถานภาพการเผยแพร่ |
ตีพิมพ์แล้ว |
วารสารมีการเผยแพร่ในระดับ |
นานาชาติ |
citation |
มี |
เป็นส่วนหนึ่งของวิทยานิพนธ์ |
เป็น |
แนบไฟล์ |
|
Citation |
0
|
|