ชื่อบทความ The 3D finite element analysis of stress distribution in implant supported single crown with different abutment designs 
วัน/เดือน/ปี ที่ได้ตอบรับ 22 กันยายน 2560 
วารสาร
     ชื่อวารสาร Engineering and Applied science Research (EASR) 
     มาตรฐานของวารสาร TCI 
     หน่วยงานเจ้าของวารสาร Faculty of Engineering, Khon Kean University 
     ISBN/ISSN  
     ปีที่ 44 
     ฉบับที่
     เดือน October-December
     ปี พ.ศ. ที่พิมพ์ 2560 
     หน้า  
     บทคัดย่อ In present the different implant abutment design are available, but the effect of abutment design to implant component and surrounding bone on implant supported single crown in posterior region is limited. The purpose of this study was to investigate the maximum von Mises stress, stress distribution pattern and stress accumulation of implant supported single crown with different abutment designs in posterior region. A dental implant (4.5 mm in diameter and 11.5 mm in length), with three different implant abutments, i.e. (1.) Rigid abutment, (2.) Transfer abutment, (3.) Customized titanium abutment, mandibular bone and all ceramic crown, were modeled with geometric data using SolidWorks software. ANSYS software was used for analysis and loads were applied as a combined load (vertical 200 N. and horizontal 40 N.) at a functional area with 1 Hz for 5 seconds. The results show that the patterns of stress distribution in all models were similar, i.e. the maximum von Mises stresses were observed at the first thread of the implant fixture on the buccal side, and in the bone the maximum stress was observed at the marginal bone contact area with the first thread of the implant. The stress was concentrated at the implant fixture-abutment screw interface in the bottom area on the buccal side. The model with customized abutment (model 3) had lower maximum von Mises stress when compared with the prefabricated abutment models (models 1 and 2) in all components except in the abutment. In conclusion a customized titanium abutment can provide better biomechanics than a prefabricated abutment. There is less maximum stress with a continuous stress distribution pattern, stress accumulation is less in the implant fixture, the stress in the abutment screw is distributed continuously with less stress concentration, and the stress is distributed uniformly to the bone with a low stress value.  
     คำสำคัญ Finite element analysis, Dental implant, Abutment design, Customized abutment, Stress distribution,  
ผู้เขียน
575130001-0 นาย พงศกร ภู่วโรดม [ผู้เขียนหลัก]
คณะทันตแพทยศาสตร์ ปริญญาโท ภาคปกติ นานาชาติ

การประเมินบทความ มีผู้ประเมินอิสระ 
สถานภาพการเผยแพร่ ได้รับการตอบรับให้ตีพิมพ์ 
วารสารมีการเผยแพร่ในระดับ นานาชาติ 
citation มี 
เป็นส่วนหนึ่งของวิทยานิพนธ์ เป็น 
แนบไฟล์
Citation 28