2012 ©
             ข้อมูลการเผยแพร่ผลงาน
การเผยแพร่ในรูปของบทความวารสารทางวิชาการ
ชื่อบทความ RECOMMENDED ILLUMINANCE LEVELS FOR VISUAL TASKS IN BUILDING 
วัน/เดือน/ปี ที่ได้ตอบรับ 2 พฤษภาคม 2562 
วารสาร
     ชื่อวารสาร Suranaree Journal of Science and Technology 
     มาตรฐานของวารสาร SCOPUS 
     หน่วยงานเจ้าของวารสาร Suranaree University of Technology 
     ISBN/ISSN  
     ปีที่  
     ฉบับที่  
     เดือน
     ปี พ.ศ. ที่พิมพ์ 2562 
     หน้า  
     บทคัดย่อ RECOMMENDED ILLUMINANCE LEVELS FOR VISUAL TASKS IN BUILDING Rojarek Seangatith, Department of Architecture, Faculty of Engineering and Architecture, Rajamangala University of Technology Isan, Nakhon Ratchasima, 30000, Thailand. E-mail: rojarek8000@gmail.com Yingsawad Chaiyakul, Faculty of Architecture, Khon Kaen University, Khon Kaen, 40002, Thailand. E-mail: yingsawad@gmail.com, cyings@kku.ac.th Abstract Illuminance recommendations in Thailand, have been adopted from western standard documents. Using adopted illuminance standards for Thai people is questioned. The main objectives of this paper are to compare visual performance under different lighting quantities of Thai people and western people and to suggest appropriate illuminance levels to perform various visual tasks for Thai people. The final part of the study compares the study results to existing lighting recommendation and legislation standards in Thailand. Firstly, visual performance of 36 subjects of various ages were tested in the lighting laboratory with the same method used in original research by Weston. Visual task used in this experiment was finding the directions of Landolt rings on different charts under six illuminance levels (5, 22, 86, 345, 1,380, and 5,510 lx). Landolt ring sizes of 4.5, 3.0, and 1.5 min. of arc and contrast of 0.97, 0.56, 0.39, and 0.28 were included. In the second part, the obtained illuminance levels were then tested for satisfaction under real situations. The results showed that average visual performance scores of Thai subjects were lower than those of Weston. However the recommended illuminance levels obtained from the study are similar to ones of Weston in every task group. When comparing the recommended illuminance levels to Thai legislations, illuminance criteria in legislations in Thailand were relatively lower. When considering the satisfaction test, the illuminance levels of IESNA were relatively low compared to the test results. Keywords: Visual performance, Illuminance, Recommendation, Thailand  
     คำสำคัญ Visual performance, Illuminance, Recommendation, Thailand 
ผู้เขียน
557200005-5 นาง รจเรข แสงอาทิตย์ [ผู้เขียนหลัก]
คณะสถาปัตยกรรมศาสตร์ ปริญญาเอก ภาคปกติ

การประเมินบทความ มีผู้ประเมินอิสระ 
สถานภาพการเผยแพร่ ได้รับการตอบรับให้ตีพิมพ์ 
วารสารมีการเผยแพร่ในระดับ นานาชาติ 
citation มี 
เป็นส่วนหนึ่งของวิทยานิพนธ์ เป็น 
แนบไฟล์
Citation 0